There is no max grid-I rating. The max rated grid dissipation is 20w,
but several experimenters have found this to be somewhat conservative
-- probably because the grid is made from Mo, which melts at 2617ºC.
Figuring grid P --- According to "Care and Feeding ... ... ..." ,
grid-dissipation is approx. the indicated DC grid current multiplied by
the RMS grid to cathode potential.
cheers, Keith
.
On Aug 15, 2005, at 7:22 PM, Keith Dutson wrote:
> What is the maximum recommended grid current for a pair of Eimac 3-500G
> tubes? Thanks.
>
> 73, Keith NM5G
>
> _______________________________________________
> Amps mailing list
> Amps@contesting.com
> http://lists.contesting.com/mailman/listinfo/amps
>
>
Richard L. Measures, AG6K, 805.386.3734. www.somis.org