On Aug 15, 2005, at 2:04 PM, Steve Thompson wrote:

>
>> -   I have observed that serious parasites in 811s can put so much EMF
>> on the filament, that it shatters into pieces and falls to the bottom
>> of the glass envelope.
>>
>>
> Even with the amp in standby?

I was not there when it happened, I saw the 3 casualties after a Ham 
brought the AL-811 over for a post mortem.  As I recall, he said he 
heard a pop after concluding the power measurement, and the three 
filaments stopped glowing.  .
>