Peter,

As the flux density changes, so does the volts per turn. M6 and Hipersil have 
the highest flux density of the CRGO steels that only have steel and silicon in 
it.

Best,

Will


*********** REPLY SEPARATOR ***********

On 4/18/05 at 9:10 AM G3rzp@aol.com wrote:
In a message dated 18/04/2005 12:28:29 GMT Standard Time, r@somis.org writes:
I have observed that Hipersil core transformers have substantially more 
volts per turn than conventional core transformers. 
Does that apply to E and I core Hipersil, or C core?

If you can run at higher flux densities, then you will get that.

73