R.Measures wrote:

Dr. William J. Schmidt, II wrote:

So you mean I can just replace my bias supply with a charged capacitor..

.since


you think the tube puts no current load on the bias supply?

If it is pure AB1, never driven into grid current, and if the capacitor and circuitry have zero leakage, then I don't see why not!



** What is going to charge the capacitor at turn-on when the capacitor is at 0v?

He said he would replace the bias supply with a CHARGED capacitor. Assuming the capacitor and the circuitry show zero leakage and he never drives the amp into ANY grid current, then he never needs to charge it again :-)


--