>The grid dissipation limit of a 3CX800 is reached at about 130 mA per 
>pair of tubes. .....
>
>73, Tom W8JI

Hmmm.  The grid dissipating rating is 5w per grid, or 10w for a pair.  If 
E = P/I, then E = 10w/0.13a =  77v.  According to Eimac's characteristic 
curves, the driving potential is roughly 30v.  Apparently, Georg Simon 
Ohm's formulas are not 'EXACTLY correct'.  

Rich---.  



R. L. Measures, 805-386-3734, AG6K   


--