Towertalk
[Top] [All Lists]

Re: [TowerTalk] Arc fault Acom 2K

To: W1JCW John <W1JCW@hotmail.com>, "towertalk@contesting.com" <towertalk@contesting.com>
Subject: Re: [TowerTalk] Arc fault Acom 2K
From: Ed Stallman <ed.n5dg@gmail.com>
Date: Fri, 9 Nov 2018 17:22:16 -0600
List-post: <mailto:towertalk@contesting.com>
I had this same problem with an Acom 2100 , changing the vacuum T/R relay was the fix .

Ed


On 11/9/2018 6:45 AM, W1JCW John wrote:
Have a strange problem in the shack.

Run the same antennas and had no issues, put in line my Yaesu 5000 and palstar 
AT.
All antennas tune flat 1:1 but when I run QRO the Acom 2K comes up with arc 
fault even with low drive of 20watts.

I can place a load at the end of the coax outside and have no issues but when I 
got to any antenna 260' center fed dipole or a vertical I get a fault and the 
amp shuts down.

Sounds like an RF issue but why now when nothing has changed outside?

Have not seen anything like this in 40yrs I've been operating.


73-
W1JCW
John

_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk



---