Towertalk
[Top] [All Lists]

Re: [TowerTalk] Arc fault Acom 2K

To: W1JCW@hotmail.com
Subject: Re: [TowerTalk] Arc fault Acom 2K
From: Jim Rhodes <jimk0xu@gmail.com>
Reply-to: jim@rhodesend.net
Date: Fri, 9 Nov 2018 12:06:05 -0600
List-post: <mailto:towertalk@contesting.com>
Amp relay not fully closed before rf? Maybe increase delay by a few
milliseconds?

On Fri, Nov 9, 2018 at 10:04 AM W1JCW John <W1JCW@hotmail.com> wrote:

> Have a strange problem in the shack.
>
> Run the same antennas and had no issues, put in line my Yaesu 5000 and
> palstar AT.
> All antennas tune flat 1:1 but when I run QRO the Acom 2K comes up with
> arc fault even with low drive of 20watts.
>
> I can place a load at the end of the coax outside and have no issues but
> when I got to any antenna 260' center fed dipole or a vertical I get a
> fault and the amp shuts down.
>
> Sounds like an RF issue but why now when nothing has changed outside?
>
> Have not seen anything like this in 40yrs I've been operating.
>
>
> 73-
> W1JCW
> John
>
> _______________________________________________
>
>
>
> _______________________________________________
> TowerTalk mailing list
> TowerTalk@contesting.com
> http://lists.contesting.com/mailman/listinfo/towertalk
>


-- 
Jim K0XU
jim@rhodesend.net
_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk

<Prev in Thread] Current Thread [Next in Thread>