Today I measured the difference in loss (dB per 100 ft) between solid copper
(SC) center conductor RG-6 vs. copper clad steel (CCS) Quad-Core RG-6 coaxial
cable. The difference is not significant until cable lengths exceed 350 feet.
You can see the affect of the steel core at 7 MHz and below in this table.
The cables were manufactured by two different companies, but the relative
measurements should be valid.
Solid Copper Cable length in
Freq Copper Clad feet for a 1 dB
MHz Loss Loss loss difference
1.8 0.3 0.6 350
3.5 0.4 0.6 500
7.0 0.6 0.8 500
10 0.7 0.85 650
14 0.75 0.9 650
21 0.9 1.0 1000
28 1.0 1.1 1000
73
Frank
W3LPL