| My guess is:   a blown diode in the power output detection circuit.
About $.50 for the part ... plus the time/labot to replace it.
73
Don
N8DE
Quoting RAY FRIESS <rayfrijr@msn.com>:
>
>
>
>
> I have a Heath SB 200 amp that is working fine with one exception.    
>  The meter is not functioning in the power out position.It reads  
> fine  for high voltage, grid, and SWR functions, just not for power   
> output.   I have to use an external wattmeter to tuneupand check   
> power output. I thought it might be just my amp until the other day   
> when I was at a ham friends of mine, and he told me he had the same   
> problemwith his SB 200. Anyone else had this problem and know what   
> to do to fix it?
> _______________________________________________
> Amps mailing list
> Amps@contesting.com
> http://lists.contesting.com/mailman/listinfo/amps
>
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
 |