> I'm changing my 2 X 3-500Z amp to a single GS-35B and in the spec's for the > tube itstates that the warm-up time is Aprox~ 2 minute. So instead of using > a power SCR in the mains to switch on the hV supply ( and probably darn slow to disengage if a fault occurs) I would like to use a Vac relay - probably close to the Plate choke since I have room in that compartment and a delay circuit is darn easy to DIY. A SCR or triac contactor will quit conducting at the next "zero axis crossing" after being turned off. (stopped being triggered) I don't think many vacuum relays can be that fast. -- Ron KA4INM - He who attacks the fundamentals of the American broadcasting industry attacks democracy itself. -- William S. Paley, chairman of CBS _______________________________________________ Amps mailing list Amps@contesting.com http://lists.contesting.com/mailman/listinfo/amps |