| To: | tentec@contesting.com |
|---|---|
| Subject: | Re: [TenTec] Scout problems |
| From: | James Boswell <jboswell@nrao.edu> |
| Date: | Thu, 23 Jul 2015 16:01:05 -0600 |
| List-post: | <mailto:tentec@contesting.com> |
Hello,Something I have done in the past, I take a needle and rub the needle shaft and point on the sticky side of masking tape. The sticky imparts to the surface of the needle and I use the needle as a probe to extract the culprit trash from the meter movement. This task takes very good light and a very steady hand. Something as small as .010 can cause those meters to "hang".
I hope this helps, 73'S
KA5SIW
> James B. Boswell JBoswell@NRAO.edu
> VLA Engineering Services Office: 575 835-7427
> National Radio Astronomy Observatory C.Phone 505 412-3732
> Post Office Box 0
> 1003 Lopezville Road
> Socorro, New Mexico 87801
|
| <Prev in Thread] | Current Thread | [Next in Thread> |
|---|---|---|
| ||
| Previous by Date: | Re: [TenTec] Scout problems, Stuart Rohre |
|---|---|
| Next by Date: | Re: [TenTec] Eagle and Zero Beating, Rick - DJ0IP / NJ0IP |
| Previous by Thread: | Re: [TenTec] Scout problems, Stuart Rohre |
| Next by Thread: | Re: [TenTec] Scout problems, Kevin Anderson |