TenTec
[Top] [All Lists]

Re: [TenTec] Centurion 422

To: <geraldj@weather.net>, "Discussion of Ten-Tec Equipment" <tentec@contesting.com>
Subject: Re: [TenTec] Centurion 422
From: pfizenmayer <pfizenmayer2@q.com>
Reply-to: Discussion of Ten-Tec Equipment <tentec@contesting.com>
Date: Wed, 15 Dec 2010 18:27:18 -0700
List-post: <mailto:tentec@contesting.com>
Nope - the meters drop 2.38 volts at 1 ma - 2380 ohms and are fed from fairly large series resistors so the 3.3 volt zeners are fine - in addition the forward diode tends to damp the meters some as they are pretty undamped.

Hank K7HP

Most meter coils drop less than 0.1 volt so 3.3 volt zener's aren't much
protection. Better to use 1N4001 single junction silicon diodes, two in
parallel opposite polarity. They won't leak any current until the drop
gets up to about .55 volt.

73, Jerry, K0CQ

73 de hank K7HP






----- Original Message -----
From:<w7ju@cox.net>
To:<tentec@contesting.com>
Sent: Wednesday, December 15, 2010 3:45 PM
Subject: [TenTec] Centurion 422


I had a 3 500Z Gas and blow a line fuse. Replaced the one tube. On turn
on in standby plate voltage is 3100 but show .2 ma plate current.
Suggestions?
Thanks
Ralph   W7JU
_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec


_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec

_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec



<Prev in Thread] Current Thread [Next in Thread>