Most meter coils drop less than 0.1 volt so 3.3 volt zener's aren't much
protection. Better to use 1N4001 single junction silicon diodes, two in
parallel opposite polarity. They won't leak any current until the drop
gets up to about .55 volt.
73, Jerry, K0CQ
73 de hank K7HP
----- Original Message -----
From:<w7ju@cox.net>
To:<tentec@contesting.com>
Sent: Wednesday, December 15, 2010 3:45 PM
Subject: [TenTec] Centurion 422
I had a 3 500Z Gas and blow a line fuse. Replaced the one tube. On
turn
on in standby plate voltage is 3100 but show .2 ma plate current.
Suggestions?
Thanks
Ralph W7JU