On 12/15/2010 5:20 PM, pfizenmayer wrote:
If you mean 200 ma not 0.2 ma - very likely a blown transistor in the 81537
FILAMENT_AC board which has the bias regulator transistors and zener on it .

Used to be a 2N3055 and a MPSU101 - and 8.2 v zener.

Later they used a ON Semi MJ15001 instead of the 2N3055 and a MPSW42 for the
MPSU101.

I suspect you will find the 3055 shorted.

I would replace both after I am in there - only hard part is unsoldering the
big transformer wire in the eyelet on the board . Rest is easy .

You might want to check cal if there was a big enuff surge - I have had the
meters get slightly demagnetized and they read low -

Been there - done that - twice - but now have 3.3volt zeners acropss both
meters so will never happen again .

Most meter coils drop less than 0.1 volt so 3.3 volt zener's aren't much protection. Better to use 1N4001 single junction silicon diodes, two in parallel opposite polarity. They won't leak any current until the drop gets up to about .55 volt.

73, Jerry, K0CQ

73 de hank K7HP






----- Original Message -----
From:<w7ju@cox.net>
To:<tentec@contesting.com>
Sent: Wednesday, December 15, 2010 3:45 PM
Subject: [TenTec] Centurion 422


I had a 3 500Z  Gas and blow a line fuse.  Replaced the one tube.  On turn
on in standby plate voltage is 3100 but show .2 ma plate current.
Suggestions?
Thanks
Ralph   W7JU
_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec


_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec


<Prev in Thread] Current Thread [Next in Thread>