On 12/15/2010 10:16 AM, Dr. Gerald N. Johnson wrote:
How about checking the control board grounding, as well as the cable
shield grounding?

Yes, cable shield connection (NOT GROUNDING) is quite important. It MUST go to the shielding enclosure on both ends. DO NOT CONNECT CABLE SHIELDS TO THE SO-CALLED "GROUND" PIN ON THE DB CONNECTOR -- IT USUALLY GOES TO THE CIRCUIT BOARD, NOT THE CHASSIS. CONNECT SHIELDS TO THE CONNECTOR SHELL!

I also recommend use of a good twisted pair, like CAT5, for serial connections. See the chapter in http://audiosystemsgroup.com/RFI-Ham.pdf about Solving Problems in the Shack, also shown in the Power Point http://audiosystemsgroup.com/HamInterfacing.pdf

73, Jim Brown K9YC