How about this:   GBPC3501  $2.92 in single lot qty.  From Mouser

Manufacturer data sheet:  http://www.fairchildsemi.com/ds/GB/GBPC3501.pdf

35amp, 100 PRV. It is a real generic non-critical part. Now what's critical is to clean the bottom of the power supply where the bridge block mounts, make sure you have some good heat sink compound but not too much and bolt the sucker in tight with the center mounting screw. If you choose, use the crimp on spade lugs but do solder the wires to the female spade terminals. When pushing the lugs on, make sure they are tight and snug. Otherwise if you have a suitable soldering iron, solder the wires direct to the bridge block.

73
Bob, K4TAX


----- Original Message ----- From: "Lew " <ljl160@verizon.net>
To: "Discussion of Ten-Tec Equipment" <tentec@contesting.com>
Sent: Tuesday, January 01, 2008 3:48 PM
Subject: Re: [TenTec] 962 Power supply Bridge rectifier needed


Thanks again for the info. A few have said the part is available but no one
seems to know the brand or part number? If anyone remembers it would be
great. Happy New Year again to everyone! Lew-KlNDV

-------Original Message-------

From: Bob McGraw - K4TAX
Date: 12/31/2007 12:14:37 PM
To: Discussion of Ten-Tec Equipment
Subject: Re: [TenTec] 962 Power supply Bridge rectifier needed

Mouser has them. {now if I could just find my Mouser catalog I'd give your
the part number}  Mouser.com and search.

73
Bob, K4TAX


----- Original Message -----
From: "Lew " <ljl160@verizon.net>
To: <tentec@contesting.com>
Sent: Monday, December 31, 2007 10:02 AM
Subject: [TenTec] 962 Power supply Bridge rectifier needed


I need the 25 amp bridge replacement for a 962 ps. Ten Tec no longer has
the
exact replacement and a mod would be needed as I was told. Not a big deal
but if I can find the exact sub, the unit can be put back the original
way.
If not, I will probably put in a heat sink and hard wire one in there.
Happy
New Year All! Lew K1NDV

PS: I got alignment info for the Omni 6 Plus.
_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec



_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec
.

_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec




<Prev in Thread] Current Thread [Next in Thread>