This may be the problem we are seeing in 2.037j with the new AGC scheme. I
found that using the slowest recovery times for each AGC setting and adding
some 'hang' fixed it. Try .21 s for slow, .17 for med and .04 for fast.
Ron N6AHA
----- Original Message -----
From: "Dick Green WC1M" <wc1m@msn.com>
To: "Ten Tec Reflector" <tentec@contesting.com>; "Orion Yahoo Group"
<orion565@yahoogroups.com>
Sent: Monday, September 11, 2006 12:20 PM
Subject: [TenTec] 2.059d: CW audio distortion in right headphone
> In 2.059d, there's a distinct clicking in the right headphone on received
> audio peaks in CW mode. This is true for both received signals and noise.
> The clicking is not present in the left headphone. It is not affected by
> the
> AGC slope setting and is not present in V1.
>
> 73, Dick WC1M
>
>
> _______________________________________________
> TenTec mailing list
> TenTec@contesting.com
> http://lists.contesting.com/mailman/listinfo/tentec
>
>
_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec
|