Henry Pfizenmayer wrote:


>  So In summation.
>
>  40 meter oscillation - be sure you have at least 8 feet of RG8 or
>  RG8X cable between the exciter and the. amp

When I first got my Centurion, it had quite low output on just 15 
meters. I called TT and the fix was...a longer jumper between the Omni 
VI and the Centurion.

Also, I had to replace my fan and, yes, you do have to remove the tubes 
and RFC.

BTW, while on the topic of the RFC, my rig was not in use for a few 
months. When I turned it on, there was a loud bang and a bright flash. 
As it turns out, the bottom end of the RFC winding vaporized, probably 
due to either dust or a spider web. (???)  It seems that the mylar 
washer between  the chassis and the bottom of the RFC is a) very thin 
and b) very narrow; i.e., the edge of this washer protrudes only about 
1/16th beyond the edge of the RFC. I made a new washer from Teflon, a 
bit thicker and larger in diameter. This and a new RFC from TT and 
problem fixed.

-73-
Carter