Talk to INRAD folks, their filters aren't near as lossy as TenTec
filters........ It might mean that you use two INRAD's one in the
500 hz position, one in the 1.8,
Dave K8bbm
On Sun, 21 Aug 2005 21:30:35 -0400
"Michael Tortorella" <w2iy@verizon.net> wrote:
Hi to the list,
I would like to use two CW filters (217 and 219) in my Omni C. It
has
positions for the 1.8 kHz (218) and 500 Hz (217) filters. Would
like to put
the 250 Hz (219) in place of the 1.8 kHz but the manual sayd the IF
amp does
not have enough gain for two CW filters. This is essentially the
same reply
I got from an inquiry to TenTec service "the IF amplifier needs to
be
modified." Has anyone done this before? Any advice and/or circuits
known
to work?
Thanks and 73
Mike W2IY
_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec
|