I got an ordinary breaker, rated fast, and got a 15 amp one.  Of course it 
isn't as fast as the AIRPAX one.  It trips about 20 amps.  Never tripped in 
service.  I thought the 27 amps trip of the 20 amp breaker was a little high.

At 04:05 PM 4/30/2005, you wrote:
>The 20.0 amp breaker actually has a trip point of 27.0 amps.  It is the
>correct one to get.
>
>Carl Moreschi N4PY
>Franklinton, NC
>----- Original Message -----
>From: "denton" <denton@oregontrail.net>
>To: "Discussion of Ten-Tec Equipment" <tentec@contesting.com>
>Sent: Saturday, April 30, 2005 3:39 PM
>Subject: Re: [TenTec] Omni VI power supply
>
>
> > will 20 amp breakers be enuff, or should I go for 22 amps..thanks.
> > ----- Original Message -----
> > From: "Carl Moreschi" <n4py@earthlink.net>
> > To: "tentec" <tentec@contesting.com>
> > Sent: Saturday, April 30, 2005 12:05 PM
> > Subject: [TenTec] Omni VI power supply
> >
> >
> > >
> > > Just add one of the AIRPAX magnetic circuit breakers in line with your
> > > supply voltage.  These breakers trip in a few milliseconds and are what
> > > TenTec used to recommend for this problem.  There was quite a discussion
> > > of
> > > these on this reflector a year or two ago.  The part number to get is
> > > T11-1-20.0A-01-11C-V.   I seem to remember there was a place in Florida
> > > where these could be ordered.
> > >
> > > Carl Moreschi N4PY
> > > Franklinton, NC
> > >> ----- Original Message -----
> > >> From: "denton" <denton@oregontrail.net>
> > >> To: "Discussion of Ten-Tec Equipment" <tentec@contesting.com>
> > >> Sent: Saturday, April 30, 2005 2:57 PM
> > >> Subject: [TenTec] Omni VI power supply
> > >>
> > >>
> > >> > I have sent my Omni VI back to TT (again) to have the finals
>replaced.
> > >> > According to Scott I need something that will shut down when the Omni
> > > goes
> > >> > into ocillation.
> > >> > Thus I am asking what power supplies the TT herd is using for Omni
> > >> > VI's.
> > >> > I can put out a want for the Omni's matching supply, but would also
> > >> > like
> > >> to
> > >> > take a look at other things...thanks.
> > >> >
> > >> >
> > >> > _______________________________________________
> > >> > TenTec mailing list
> > >> > TenTec@contesting.com
> > >> > http://lists.contesting.com/mailman/listinfo/tentec
> > >>
> > >
> > > _______________________________________________
> > > TenTec mailing list
> > > TenTec@contesting.com
> > > http://lists.contesting.com/mailman/listinfo/tentec
> > >
> > >
> >
> >
> > _______________________________________________
> > TenTec mailing list
> > TenTec@contesting.com
> > http://lists.contesting.com/mailman/listinfo/tentec
>
>_______________________________________________
>TenTec mailing list
>TenTec@contesting.com
>http://lists.contesting.com/mailman/listinfo/tentec

73,  Chas,  W1CG 

_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec

<Prev in Thread] Current Thread [Next in Thread>