N0KHQ@aol.com wrote:
> 2. Slow sweep display and intermittent freezing when in the "Sub RX"
> mode and you push
> one of the buttons (AN, NR. etc) below the display. (returns to normal after
> reboot)
I did some measurements recently and it seems that SWEEP hardware
takes a single 4 ms sample every 2 seconds. This represents
0.2 % chance of hitting upon a short (intermittent) signal,
and 99.8 % chance of missing it. Hardly a real time show.
Looks like TenTec does some interpolation - the display
updates several times per second, but no new samples
are taken. In other words, most of updates are faked.
73,
Sinisa YT1NT, VE3EA