Anibal: Anibal Dos Ramos escribió: Hi All If the meter needle (at Ic position of the switch) moves shaky, then most probably driver or final stage is auto-oscillating while the tune-up procedure. try to start listening, them i realice the position in the preselect is not giving the maximun noise, but, if i move it in order to get the higher noise then i will loose the power in TX... :-/ Yes, you must do a complete re-alignment as per manual instructions, this happens because there's one shared rx-tx stage but the other two are not. So, because of lack of tracking, for rx you have a different setting of preselector than for tx. And is most notable at higher frequency bands. I suggest you first verify the oscillation issue checking both neutralizations and then perform the realignment. Also, check the coupling capacitor between driver plate and final grid tubes; it becomes lossy after some time. Goooooood luck :) Guillermo - LU8EYW.