FYI there is no control cable. All control voltages go through the coax.
Doug
-----Original Message-----
From: TowerTalk [mailto:towertalk-bounces@contesting.com] On Behalf Of john
simmons
Sent: December 11, 2024 7:04 AM
To: towertalk@contesting.com
Subject: Re: [TowerTalk] Ameritron RCS-4 Remote Coax Switch
Dick,
I don't think you have a problem with the choke, you have a problem with
stray RF. Have grounded the frame of the relay box? I would suggest wrapping
10 turns of the control cable on a toroid.
73
-de "Curly" John NI0K
QRZ.com<https://www.qrz.com/db/ni0k>
Hamshack Hotline<https://hamshackhotline.com/> call me: 6100271
On 12/10/2024 5:03 PM, RVZ via TowerTalk wrote:
Hi Guys,
I've gotten a lot of good use out of Ameritron RCS-4 Remote Coax Switches.
However, I keep smoking RFC-1 and wonder if you can recommend a Heavy Duty
replacement for RFC-1 that I'm less likely to smoke when running a KW?
Thanks! Dick- K9OM
_______________________________________________
_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
|