Re: [TowerTalk] Ameritron RCS-4 Remote Coax Switch

To: "'john simmons'" <jasimmons@pinewooddata.com>, <towertalk@groups.io>, <towertalk@contesting.com>
Subject: Re: [TowerTalk] Ameritron RCS-4 Remote Coax Switch
From: "Doug Renwick" <ve5ra@sasktel.net>
Date: Wed, 11 Dec 2024 09:21:50 -0600
List-post: <mailto:towertalk@contesting.com>
FYI there is no control cable. All control voltages go through the coax.

Doug

-----Original Message-----
From: TowerTalk [mailto:towertalk-bounces@contesting.com] On Behalf Of john
simmons
Sent: December 11, 2024 7:04 AM
To: towertalk@contesting.com
Subject: Re: [TowerTalk] Ameritron RCS-4 Remote Coax Switch

Dick,

I don't think you have a problem with the choke, you have a problem with
stray RF. Have grounded the frame of the relay box? I would suggest wrapping
10 turns of the control cable on a toroid.

73
-de "Curly" John NI0K
QRZ.com<https://www.qrz.com/db/ni0k>
Hamshack Hotline<https://hamshackhotline.com/> call me: 6100271

On 12/10/2024 5:03 PM, RVZ via TowerTalk wrote:

Hi Guys,
 I've gotten a lot of good use out of Ameritron RCS-4 Remote Coax Switches.
However, I keep smoking RFC-1 and wonder if you can recommend a Heavy Duty
replacement for RFC-1 that I'm less likely to smoke when running a KW?
Thanks!  Dick- K9OM