All the military systems I worked on required an application of Dow Corning 4 
dielectric grease to connectors. That was placed on threads, male and female 
contacts, and environmental sealing components. Only a very thin film is 
applied. Every RF connector I install today has it in the threads and on the 
contacts. Its hydrophobic properties are primary here in preventing long-term 
corrosion due to unavoidable trace condensation.

-Gary NA6O

> After 15 years, a pair of PL-259 connectors have seized on mating SO-239
> jacks used on an outdoor RF choke. Is there anything more suitable than
> Penatrox-A which is Au/Cu rated?  Ideally, I'd like to apply a synthetic +
> conductive grease on the mating SO-239 threads.
> 