Towertalk
[Top] [All Lists]

Re: [TowerTalk] Rohn Tower Pier Pin install

To: "'CEPitts'" <cpitts@ec.rr.com>, <towertalk@contesting.com>
Subject: Re: [TowerTalk] Rohn Tower Pier Pin install
From: "Jeff DePolo" <jd0@broadsci.com>
Date: Thu, 18 Feb 2021 12:49:28 -0500
List-post: <mailto:towertalk@contesting.com>
> I am using Rohn products and yheir guidance from the their book and my
> question is the correct way to install the 3/4" x 12 pin into the concrete ba 

For one of the smaller Rohn tower series that have a flat baseplate, the pier 
pin is really there only to keep the base from moving laterally during 
erection.  Once there is vertical load on the baseplate from the dead weight of 
the tower sections plus the guy wire reactions, the pier pin should not be 
considered, or even relied on, as a structural element - if that's not the 
case, then the tower has other, major, issues. 

Whether it is set into the pour or inserted into a hole after the concrete is 
cured doesn't matter whole lot.  It's easier to set it into the mud though, and 
(mostly) gets around the issue of water being able to get into the hole if you 
were to drill and epoxy the pin.

For a larger tower with an articulated base (as opposed to a flat baseplate), 
the pier pin is arguably more of a structural element, particularly under 
worst-case wind conditions, that should be included in the analysis and design.
 
                                        --- Jeff WN3A



-- 
This email has been checked for viruses by Avast antivirus software.
https://www.avast.com/antivirus