Re: [TowerTalk] RFS LCF158-50JA 1-5/8" Heliax

To: "'Byron Tatum'" <bjtatum1@att.net>, <towertalk@contesting.com>
Subject: Re: [TowerTalk] RFS LCF158-50JA 1-5/8" Heliax
From: "Jeff DePolo" <jd0@broadsci.com>
Date: Tue, 23 Jul 2019 11:04:06 -0400
List-post: <mailto:towertalk@contesting.com>
Your email came through as one big block so I'm not going to bother quoting.

1.  Don't use Commscope/Andrew AL connectors on RFS.

2.  D01K "Premium" connectors have better PIM performance, but there's no
reason to need them for your non-duplex or non-multi-carrier installation.
For your intended use, I'd stick with older versions like 072, especially if
you like the "longer finger" design of the Commscope connectors, although I
don't believe your concerns are warranted if the connectors are properly
installed.  Keep in mind that the current flow is on the *outside* of the
center conductor, not the inside, so having more "depth" inside the center
conductor as far as contact goes doesn't buy you anything.

3.  Integral weatherproofing in the form of O-rings at both the interface
and connector body is "a good start" but it isn't a replacement for real
external weatherproofing.

                                --- Jeff WN3A


---