Towertalk
[Top] [All Lists]

Re: [TowerTalk] Fall Zone

To: towertalk@contesting.com
Subject: Re: [TowerTalk] Fall Zone
From: jimlux <jimlux@earthlink.net>
Date: Mon, 8 Jul 2019 10:36:36 -0700
List-post: <mailto:towertalk@contesting.com>
On 7/8/19 9:34 AM, Jim Thomson wrote:
Date: Mon, 8 Jul 2019 11:20:31 -0400 (EDT)
From: Wilson  Lamb <infomet@embarqmail.com>
To: undefined <towertalk@contesting.com>
Subject: [TowerTalk] Fall Zone

<I wouldn't want a neighbor's tower/Yagi looming over my backyard...and I love 
towers!
<The fall zone idea seems like simple good manners.
<I have been loosely involved in dropping 200' BC towers, dropped by cutting 
the rods at one guy anchor, thus losing all guys on that side.
<They fell absolutely full length, with a few sections not even bent!
<I think a foundation failure (soil, bolt, gin pole) would drop a crankup to 
full length.
<Is there any experience available on this?
<WL

##  per software,  Trylon self support  towers will  fail  at the junction  of the 4th 
 and  5th  section..... 40’  above ground.
UST  designs a weak  spot.... which  is  midway  up  the  3rd  section...  46.5 
 feet  above ground.

##  Never seen  a pix  of  either  tower folded  over... as  depicted  above.   
 40  ft...and  46.5 ft.   So dont  know if  their
design theory  works....or not.


It doesn't have to be a specially designed weak spot. Towers tend to bend/buckle in the middle anyway.