I am sure there  is NO  mechanical advantage of dual thimbles over and ceramic 
egg insulator.

I my self have never witnessed the dual thimble  configuration on and 
commercial towers.  The one’s with none conductive guys or none conductive 
insulator rods all use (Johnny Balls) egg insulators. To terminate to EHS 
strand wire .

One other thought  as a Belt and Suspender Type … The thought of two metals at 
friction points = noise to me…. On one of my towers  just the thimbles into the 
guy wire flange  ( Rohn 65) noise was traced two sources   1 the guy attachment 
point   and  at the Tic Ring rotating ring…. One requires a  whisker  that rode 
along the ring flange as it rotated and all thimble to guy attachment points  
had  ground brads  attached from the guy grips the tower legs…

YMMV



Wayne W3EA



Sent from Mail<https://go.microsoft.com/fwlink/?LinkId=550986> for Windows 10



________________________________
From: TowerTalk <towertalk-bounces@contesting.com> on behalf of Dick Green WC1M 
<wc1m73@gmail.com>
Sent: Tuesday, May 22, 2018 5:58:48 PM
To: john@kk9a.com; towertalk@contesting.com
Subject: Re: [TowerTalk] Joining EHS Guy To Philly Guy

I use guy grips with back-to-back thimbles inside the loops.

73, Dick WC1M

-----Original Message-----
From: john@kk9a.com <john@kk9a.com>
Sent: Tuesday, May 22, 2018 6:40 AM
To: towertalk@contesting.com
Subject: [TowerTalk] Joining EHS Guy To Philly Guy

There is nothing wrong with using the insulators however I am not sure what 
good they do since Phillystran is not conductive. I have been using back to 
back thimbles on 6700# and 11200# guys for decades without issue.

John KK9A



Allan W Schlaugat N9ISN

this 155ft tower will be Phillystran with a short EHS chunk, about 10-20 feet 
long, near the ground where it attaches to the guy anchor plate.
My query is what would be the prudent and safest/strongest method to join that 
EHS guy cable to that Philly cable? I have a box full of Rohn 502 insulators 
and I was thinking of using those. Any better alternatives?

Thanks!  73   Al   N9ISN



_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk

<Prev in Thread] Current Thread [Next in Thread>