| To: | "towertalk@contesting.com" <towertalk@contesting.com> |
|---|---|
| Subject: | Re: [TowerTalk] S21 to Rp & Cp - Equivalent Circuit |
| From: | Steve Hunt <steve@karinya.net> |
| Date: | Fri, 12 Jan 2018 15:57:47 +0000 |
| List-post: | <mailto:towertalk@contesting.com> |
Yes!!!! - S11 Magnitude and Phase are quite different from S21 Magnitude
and Phase.
If you are interested, here's how I derive the choke's complex impedance from S21 Magnitude and Phase: http://www.karinya.net/g3txq/chokes/s21.pdf Steve G3TXQ On 12/01/2018 15:50, Máximo EA1DDO_HK1H wrote: Is a different formula to convert LogMag(dB) & Phase from S11 than from S21? ________________________________ _______________________________________________ _______________________________________________ TowerTalk mailing list TowerTalk@contesting.com http://lists.contesting.com/mailman/listinfo/towertalk |
| Previous by Date: | Re: [TowerTalk] S21 to Rp & Cp - Equivalent Circuit, Máximo EA1DDO_HK1H |
|---|---|
| Next by Date: | Re: [TowerTalk] S21 to Rp & Cp - Equivalent Circuit, jimlux |
| Previous by Thread: | Re: [TowerTalk] S21 to Rp & Cp - Equivalent Circuit, Máximo EA1DDO_HK1H |
| Next by Thread: | Re: [TowerTalk] S21 to Rp & Cp - Equivalent Circuit, jimlux |
| Indexes: | [Date] [Thread] [Top] [All Lists] |