Date: Wed, 15 Nov 2017 09:24:41 -0600
From: "Jeff" <keepwalking188@ac0c.com>
To: <towertalk@contesting.com>, "Patrick Greenlee"
<patrick_g@windstream.net>
<What about insulated stranded? You give up some of the ground to conductor
<surface area but the wire compared to the rods is a pretty minimal part of
<the network. Right?
<73/jeff/ac0c
<www.ac0c.com
<alpha-charlie-zero-charlie
## on advice of my electrician buddy, who is also a ham, I used,
2 gauge, stranded CU, insulated. Called RW-90. Then cadwelded
at rod ends. And compression lugs used at tower end. I also used
RW-90 in 10 and 8 gauge, for wire ants. That stuff last forever
outdoors. Solid 2 gauge is a bitch to work with. And yes, lightning
will do multiple 90 deg bends.
Jim VE7RF