Wes, I have seen the termination loop fail on that style guy termination. I see the rating is 90% of the guy rated breaking strength. On the other hand, I have seen cases using Big Grips that a guy broke and the grip was still intact. Big Grip rating is 100% of the guy rated breaking strength. 73, Gerald K5GW GM Texas Towers 800 272 3467 In a message dated 12/27/2016 1:40:58 P.M. Central Standard Time, wes_n7ws@triconet.org writes: http://www.endurancehardware.com/5guysttevi.html _______________________________________________ _______________________________________________ TowerTalk mailing list TowerTalk@contesting.com http://lists.contesting.com/mailman/listinfo/towertalk |