Towertalk
[Top] [All Lists]

Re: [TowerTalk] Pulling long length of 7/8 hardline in conduit

To: <towertalk@contesting.com>
Subject: Re: [TowerTalk] Pulling long length of 7/8 hardline in conduit
From: <john@kk9a.com>
Date: Sat, 3 Sep 2016 23:10:25 -0000
List-post: <towertalk@contesting.com">mailto:towertalk@contesting.com>
That is a good idea! I use inexpensive 4" drain pipe as conduit and no
sweeping fittings are available.  I used two 45's instead of a single 90
degree fitting but it still creates a lot of resistance. 

John KK9A


To:     towertalk@contesting.com
Subject:        Re: [TowerTalk] Pulling long length of 7/8 hardline in
conduit
From:   Patrick Greenlee <patrick_g@windstream.net>
Date:   Sat, 3 Sep 2016 16:15:17 -0500
List-post:      <towertalk@contesting.com">mailto:towertalk@contesting.com>
Gentle turn radius sweeps can be made for 3 or 4 inch diameter PVC DYI using
a heat gun (cheap one from Harbor Freight) by heating sand filled PVC
conduit. The sand keeps the PVC conduit from collapsing and kinking and is
easily removed when done. Do not heat near the end or continue the bend too
close to the end as it can distort the shape and make it not fit into a
fitting.

Patrick        NJ5G

_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk

<Prev in Thread] Current Thread [Next in Thread>