List-post: | <towertalk@contesting.com">mailto:towertalk@contesting.com> |
On Sun,4/24/2016 10:03 AM, Jim Thomson wrote: Never heard of silver plated steel being used b4. That would be fine above about 10 MHz, but steel coated with anything greatly increases conductor resistance below a few MHz as compared with solid copper. You can see this in Belden's published data for their cables. 73, Jim K9YC _______________________________________________ _______________________________________________ TowerTalk mailing list TowerTalk@contesting.com http://lists.contesting.com/mailman/listinfo/towertalk |