You can make a serving tool from a 1" wide X 1/8th" thick, maybe 6" long with a hole large enough to easily pass a single strand, (be sure to remove sharp edges) but it's tedious work and may have a learning curve. It works well, but for lack of a better term is a royal PITA.

Serving might take an explanation for many hams <:-))


73

Roger (K8RI)



On 6/8/2015 12:36 PM, TexasRF--- via TowerTalk wrote:
Correct, and the specified Crosby clamps are the forged type,  3/16CCF.
More popular for ham use is the  3/16CCM, which is a  malleable clamp having
lower strength and much lower cost. It has been a  very long time since hot
dipped galvanized malleable clamps have been readily  available. We only have
plated ones in stock and only for those that insist; we  do not recommend
their use.
Conceptually one could use more than three clamps to achieve greater
strength. I have never seen data for that though. Originally the Rohn
recommendation when cable clamps were used involved also serving the seven guy  
wire
strands for added strength. This is a really nasty job that few hams would
actually complete. Rohn even sold tool for that; CST which was easily
duplicated.
For many years the Big Grip BG2142 and BG2144 have been the termination
product of choice. They install in a fraction of the time needed for cable
clamps and serving the cable ends. The grips are very price competitive with
the  CCF style clamps that were the prior choice.
I saw the note about using Chinese insulators with Big Grips. There are
some insulators available that are way too small to be used with grips and I
can  see that as a problem. The correct insulator is model 502 from the most
popular  insulator manufacturers. There is a different part number for
lesser known  manufacturers and I don't know the numbers.
The only way I can see that the proper insulator could damage a Big Grip is
  if it shattered under load or from flying debris in a storm. I personally
have  never seen or heard of that happening. To reiterate: with a proper
sized  insulator.
73,
Gerald K5GW
GM Texas Towers
In a message dated 6/8/2015 10:56:40 A.M. Central Daylight Time,
towertalk@contesting.com writes:

  Does anyone know of a vendor who stocks original  style  heavily
galvanised clamps similar or identical to the older  3/16CCM? Based on
what I paid
in 1980 and on-line inflation  calculators, these should now run a  little
over $1.00  apiece.

Well, I don't know if there ever sold for a  buck  but the industry
standard for years has been Crosby clamps.  Available in lots of  places.

Cheers,
Steve     K7LXC
TOWER TECH
_______________________________________________



_______________________________________________
TowerTalk  mailing  list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk

_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk


--

73

Roger (K8RI)


---
This email has been checked for viruses by Avast antivirus software.
https://www.avast.com/antivirus


_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk

<Prev in Thread] Current Thread [Next in Thread>