I'm slowly building up a 40 meter Moxon Beam and the boom needs to be somewhere 
between 24 and 27 foot long depending on the article used to build it.  The 
boom has me stuck.  As all of you know, most aluminum is sold in 6 foot lengths 
for shipping purposes.  That means the tubes need to be connected.  I'm at the 
point where I need to determine what I am going to use for boom material and 
how to connect the segments.  

I have some 2 1/2 inch aluminum tubing I bought surplus many years ago.  The 
stuff has a wall thickness of around 1/16th inch thick and is hard aluminum, 
probably 6061 alloy.  I've got plenty of it in 6 foot lengths.  It's gorgeous 
looking tubing and I initially figured and wanted to use it for my boom 
material.  However, I have been racking my brain out trying to figure out how 
to join the sections.  (The inside diameter is around 2 3/8th inches ID.) I 
tried 2 inch schedule 40 pipe and it is a tad too large in diameter to fit into 
this 2 1/2 inch OD tubing with an approximate 2-3/8 inch ID. (I thought maybe 
sanding down some schedule 40 aluminum pipe but would I get it to really work?) 
 I thought maybe turning some oak down to a diameter to fit inside this tubing, 
 I have hunted high and low for some aluminum stock to either snuggly fit 
inside or outside this pipe with no success.  If I buy 3 inch OD tubing, it 
will have an ID of 2-3/4 inches.  I even thought of slicing the 
 ends open in the form of a cross in some 3 inch tubing and then use hose 
clamps to secure things, but then the pipe would only be tight on one end of 
the joining pipe. I thought maybe of slicing the 3 inch pipe open along it's 
length and then use hose clamps to pull it tight and together again around my 
existing pipe.  The bottom line is I have not been able to figure out how to 
use my tubing satisfactorily.  I'm now starting to think maybe my tubing is not 
the answer for my needed boom material.  That really seems like a big waste as 
I know if I bought this tubing new it would run big bucks.  A 40 meter Moxon is 
no small antenna so the boom material needs to be decent and adequate for my 
purpose.

That said,  am I missing something here?  Anyone on here who could get me on a 
proper path?  I need to either find of way to use my existing 6 foot lengths of 
2-1/2 OD tubing with a 2-3/8th inch ID or move on to something else for the 
boom. I'd sure appreciate hearing from you experts as my quandary has been 
bugging me for weeks now. Right now I am just spinning my wheels going nowhere. 
 I might add, I do not have a machine shop at my QTH.  I thought I would try 
one last time to figure out how to use my tubing before I give up on that idea 
by asking you guys for advice.  Any and all comments would really be 
appreciated.

Lee, w0vt