You're correct that any power dissipation due to the voltage will be twice the matched case dissipation. But I thought - perhaps mistakenly - we were still discussing voltage breakdown?

Steve G3TXQ



On 02/08/2014 21:25, Richard (Rick) Karlquist wrote:

Yes, we all know this, but power loss is proportional to the
SQUARE of the voltage, so it is doubled for 2:1 SWR in the worst
case.  Am I missing something?