On 5/20/2014 Jim Brown wrote:
> Honda generators put out trash as a common mode signal on the green
> wire. It is NOT acceptable to choke the green wire, but it IS acceptable
> to choke all three conductors.
Yeah, I noticed this first time I used it. I made up a little pigtail
extension cord, and used a type 31 ferrite. Forget the exact model,
but it is about 2.5" long with about a 1" or so inner diameter. Made
3-4 passes (can't remember, not going to go out and count), but I took
the end off an old extension cord, and put a new end on. Put the
appropriate plug on the other remaining part so I could still use that
too. I use
that between the genny and anything I need to plug in - no noise
after that
--
Charlie