Vermont is something similar: 1 inch soil on top, infinite layer of mixed rocks 
for the rest.


Hans - N2JFS



-----Original Message-----
From: Gary Smith <Gary@ka1j.com>
To: towertalk <towertalk@contesting.com>
Sent: Wed, Apr 23, 2014 9:22 am
Subject: Re: [TowerTalk] Ground Rod Myths?


I used to live in NE Illinois and in southern Louisiana and that's 
exactly how I did my long grounding rods. No stones at all to run 
into. Here in Connecticut it took a lot of effort to find exact 
placement for my HI-Z Rx array, the soil is one big rock with a thin 
surface layer dirt on top. Get a few inches down & hit solid.

73,

Gary
KA1J

> On 4/22/2014 10:24 PM, GARY HUBER wrote:
> > Here in rural Illinois, where the soil has not been compacted, often 
> > we can dig a cup size starter hole, fill it with water, stand the 
> > ground rod in the water and then push the rod down as far as it will 
> > go then pull it up add water, push the rod down, pull up, add water, 
> > and repeat the cycle until the rod is in as far as we need it.  In 
> > most cases no tools are needed, maybe two gallons of water, and no 
> > more than twenty minutes per rod.
> >
> 
> 
> I'd say that indicates one whale of a big base for towers, be they self 
> supporting or guyed!  One big rain and your guyed tower would be a 
> section shorter<:-))
> 
> 73
> 
> Roger (K8RI)
> 
> 
> > 73 & DX,
> > Gary - AB9M
> >
> > -----Original Message----- From: Tony
> > Sent: Tuesday, April 22, 2014 6:06 PM
> > To: towertalk@contesting.com
> > Subject: [TowerTalk] Ground Rod Myths?
> >
> > All:
> >
> > I came across a website that claimed it's better to use the hydraulic
> > pressure from water hose to drive ground rods instead of pounding them
> > into the ground. The idea is to prevent damage to the copper clad. I can
> > see how this would make the installation easier, but can't imagine the
> > copper being stripped away that easily.  Any truth to this?
> >
> > The site also mentioned that the copper strap or wire that joins one
> > ground rod to the next should be buried at least a foot below ground
> > level while another said a few inches is fine. I suspect deeper is 
> > better.
> >
> > Thanks...
> >
> > Tony


---
This email is free from viruses and malware because avast! Antivirus protection 
is active.
http://www.avast.com

_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com