oh  I forgot
I did this at the
 top of the tower, at the bottom of the tower and where the cable enters my 
shack.
 
I also grounded the blue wire and shield at the back of the Green Heron box 
inside the shack 
Mark N1UK
----- Original Message ----- 
From: "Mark Robinson" <markrob@mindspring.com>
To: "Ray Benny" <rayn6vr@cableone.net>; "TowerTalk" 
<TowerTalk@contesting.com> 
Sent: Wednesday, 20 November, 2013 3:20 PM
Subject: Re: [TowerTalk] Wire grounding question
 I have a Green Heron controller driving an M2 rotator. It uses a magnetic 
pulse encoder.
I had a red and blue wire inside a foil shield with a drain wire inside. I 
grounded the drain wire and I also grounded the blue wire. I did this at 
the top of the tower, at the bottom of the tower and where the cable 
enters my shack. 
I connected MOV's between the grounded blue wire and the red wire at the 
base of the tower and where the cable enters my shack.  I have had no 
issues with this set up 
Mark N1UK
----- Original Message ----- 
From: "Ray Benny" <rayn6vr@cableone.net> 
To: "TowerTalk" <TowerTalk@contesting.com>
Sent: Wednesday, 20 November, 2013 2:08 AM
Subject: [TowerTalk] Wire grounding question
 I am using a K7NV prop-pitch rotator for my almost completed tower 
project.
For the encoder (magnetic pulse counter) that is mounted inside the PP
motor, I am using a 2 pair small wire cable that has an aluminum foil
shield and ground wire. I will be installing a lightning arrestor at the
base of the tower for these two conductors.
My question, should I ground this foil shield or leave it floating at 
both
ends (PP rotator and rotator control box)? I would think that it should 
be 
grounded, but does it matter?  Any consequences if I do or don't?
Ray,
N6VR
_______________________________________________
_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
 
_______________________________________________
_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk 
_______________________________________________
_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
 |