Well, its not a standard rohn design, at least up to rohn 55g. at 230' a
rohn 55g would have 5 levels of guying with a radius of 184'. But it could
easily be a much stiffer and fatter tower than 55g. or it could be a
special design for low wind zone with smaller antenna loading.
David Robbins K1TTT
e-mail: mailto:k1ttt@arrl.net
web: http://wiki.k1ttt.net
AR-Cluster node: 145.69MHz or telnet://k1ttt.net
-----Original Message-----
From: TowerTalk [mailto:towertalk-bounces@contesting.com] On Behalf Of Greg
Kozisek
Sent: Wednesday, October 30, 2013 19:28
To: towertalk@contesting.com
Subject: [TowerTalk] minimum guy radius
235' tower with anchors at 100', three guy levels. Ever heard of such a
thing? Is it possible? Oversized or undersized wires? I haven't seen it, but
it sounds bizarre to me.