I have a couple of the Array Solution lightning protection boxes and I think 
that they would be a good choice for your rotator cables.  Polyphaser makes one 
and I have them as well, but they are more pricey.  MOVs cost around $1 each 
and you could also make your own protection circuit.

John KK9A


To:  towerTalk@contesting.com 
Subject:  [TowerTalk] Lighnting Protection 
From:  jd_hudson@comcast.net 
Date:  Tue, 6 Dec 2011 03:53:21 +0000 (UTC) 
 

Whats everyone using for lightning protection for rotor cables (8 conductor) 
and STEPPIR control cables (16 conductor). I'm looking at the ARRAY SOLUTIONS 
sets but would like to check out all the other setups, if there are any? 


Setup is 55' crankup with 4 element STEPPIR, inverted L , GS10000 Yaesu rotor 
at 135' from the shack. Polyphasers on the coax and a Ameritron coax switch at 
the tower. 


Any help is appreciated 


John 