I used MOV's with 0.1uF caps across them. This is what the Array Solutions
box does. I tailored the MOV's for the 12v lines and the higher DC voltage
motor lines for my M2 rotator.
Mark N1UK
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
----- Original Message -----
From: <jd_hudson@comcast.net>
To: <towerTalk@contesting.com>
Sent: Monday, 05 December, 2011 10:53 PM
Subject: [TowerTalk] Lighnting Protection
> Whats everyone using for lightning protection for rotor cables (8
> conductor) and STEPPIR control cables (16 conductor). I'm looking at the
> ARRAY SOLUTIONS sets but would like to check out all the other setups, if
> there are any?
>
>
> Setup is 55' crankup with 4 element STEPPIR, inverted L , GS10000 Yaesu
> rotor at 135' from the shack. Polyphasers on the coax and a Ameritron coax
> switch at the tower.
>
>
> Any help is appreciated
>
>
> John
> KO4XJ