Towertalk
[Top] [All Lists]

Re: [TowerTalk] Hardline connector selection

To: Drax Felton <draxfelton@gmail.com>
Subject: Re: [TowerTalk] Hardline connector selection
From: Dan Hearn <n5ardxcc@gmail.com>
Date: Fri, 15 Jul 2011 11:44:50 -0700
List-post: <towertalk@contesting.com">mailto:towertalk@contesting.com>
Some Andrews heliax has a ridge on the copper shield which spirals as it
advances while other Heliax has concentric ridges and they need different
connectors.

73, Dan, N5AR

On Fri, Jul 15, 2011 at 10:16 AM, Drax Felton <draxfelton@gmail.com> wrote:

> If I have 7/8 hardline of an unknown type (likely Andrews since the guy i
> got it from had tons of andrews parts) how do I determine which end
> connectors to use?
>
> For example what is the difference between these two from Nebraska Surplus
> Sales?
>
> (CRF) L5NM
> " N" male fits 7/8" Heliax LDF5-50A or Cablewave FLC78-50. Andrew, new in
> the box.
>
> (CRF) FLC-78-50
> Type "N" male for concentric "ribbed" 7/8" Cablewave FLC78-50 hardline or
> Andrew LDF5-50A Heliax. Same function as L5NM.
>
> kb3x
> _______________________________________________
>
>
>
> _______________________________________________
> TowerTalk mailing list
> TowerTalk@contesting.com
> http://lists.contesting.com/mailman/listinfo/towertalk
>
_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk

<Prev in Thread] Current Thread [Next in Thread>