Hook the 259b to the coax/unbalanced side, and hook a 50 ohm non-inductive
resistor across the balanced terminals. Read the impedance on the 259b and
that will tell you the transformation... if it reads 50 ohms its 1:1, if it
reads 25 ohms its 2:1, etc.
David Robbins K1TTT
e-mail: mailto:k1ttt@arrl.net
web: http://www.k1ttt.net
AR-Cluster node: 145.69MHz or telnet://dxc.k1ttt.net
> -----Original Message-----
> From: towertalk-bounces@contesting.com [mailto:towertalk-
> bounces@contesting.com] On Behalf Of KC2PCR
> Sent: Saturday, December 06, 2008 15:52
> To: towertalk@contesting.com
> Subject: [TowerTalk] Testing a Balun
>
> Hello & Happy Holidays to All!
>
>
>
> I would be interested to know what the procedure would be to perform a
> test
> on a balanced to un-balanced transformer (balun) like the Unadilla W2AU to
> determine It's value and also if its working properly. IE: values= 1:1 ,
> 4:1
> , 9:1 etc.
>
> I have a 259B analyzer and a bench style muli-meter as available test
> equipment, and would obtain whatever else may be needed.
>
> My apologies in advance for a poor understanding in the area of antenna
> current & impedance, it isn't from a lack of trying ;)
>
> Thanks & 73
>
> Doug - kc2pcr
>
> Oneida Lake, NY
>
> _______________________________________________
>
>
>