In a message dated 10/9/2008 9:03:10 A.M. Pacific Daylight Time,
towertalk-request@contesting.com writes:
> I have a LM-470D tower that was restrung with Stainless Steel cable ( 1
size
larger than what
the stock galvanized cable was ) but the guy did not replace the thimbles
and they are
pretty rusty and am thinking I should replace them before putting tower back
into operation
Hmm. I've got a couple of concerns. First, what did the manufacturer say
about replacing the cables with a larger size? I guess that if the new size
fits the pulleys, it's probably not a fatal problem.
While SS cables would seem to be an upgrade to the galvanized ones, they
do have a built-in problem in that they can gall and create hard spots in
the cable. While good for sailboats and other non-moving applications, the
galvanized version is the one for moving loads.
Is Sandy Eggo (San Diego) that bad on crank-up cables?
Cheers,
Steve K7LXC
TOWER TECH
**************New MapQuest Local shows what's happening at your destination.
Dining, Movies, Events, News & more. Try it out!
(http://local.mapquest.com/?ncid=emlcntnew00000001)
_______________________________________________
_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com