Hi guys,
I'm preparing to install a Telex-Hygain HG52SS, 3 section, 52ft,
crank-up/tilt over, tower. This is a self-supporting tower if you make the
base 3'x 3'x 6'. Windload 9.5 sq.ft.
I want to make a less permanent installation as we may be out of this place
in a couple of years. Therefore I was thinking of making the base approx.
2'x 2'x 2' and guy the bottom section (3 or 4 guys) at 20 ft. I'm going to
use screw anchors for the guy wires. Sandy soil. Windload approx. 15 sq.ft.
Ideas and comments greatly appreciated. Thanks.
73 Bert, VE3OBU