Towertalk
[Top] [All Lists]

Re: [TowerTalk] Coax

To: Charles Gallo <Charlie@TheGallos.com>
Subject: Re: [TowerTalk] Coax
From: jimlux <jimlux@earthlink.net>
Date: Wed, 23 Jul 2008 06:15:22 -0700
List-post: <towertalk@contesting.com">mailto:towertalk@contesting.com>
Charles Gallo wrote:
> 
> On 7/22/2008 K7LXC@aol.com wrote: ...snip...
>> 
>> So for RG-8 the minimum bending radius is 20  inches?!? I don't
>> think so. As I recall, the multiple is 6, giving you a 3"  radius.
>> It's higher for Andrew Heliax and other high grade coaxes but I
>> don't  recall the specifics.
> ...snip...
> 
> Per NASA "Coaxial cables shall not be bent below the minimum
> recommended inside bend radius (6 diameters for flexible, 2 diameters
> for semi-rigid and rigid)."
> 
> see:
> http://workmanship.nasa.gov/lib/insp/2%20books/links/sections/404%20Coaxial.html
> 
> 
> 

And I suspect that this standard doesn't apply to Heliax and similar styles.

There would almost always be a requirement that one follow the 
manufacturer's recommendation, as well.

Jim