On 7/22/2008 K7LXC@aol.com wrote:
...snip...
>  
>     So for RG-8 the minimum bending radius is 20  inches?!? I don't think so.
> As I recall, the multiple is 6, giving you a 3"  radius. It's higher for
> Andrew Heliax and other high grade coaxes but I don't  recall the specifics.
...snip...

Per NASA
"Coaxial cables shall not be bent below the minimum recommended inside bend 
radius (6 diameters for flexible, 2 diameters for semi-rigid and rigid)."

see: 
http://workmanship.nasa.gov/lib/insp/2%20books/links/sections/404%20Coaxial.html

--  