On 07/07/08 05:37 pm Roy & Peggy Bonvillian wrote:
> I have just set my base for my 55G and have my UFER ground wires that need
> to be connected to the legs of the tower. I have 3 #4 gauge wire coming out
> of the cement near each leg. My question is where do I fine the proper
> clamps to connect the bare copper wire to the 3 legs and also have a place
> to tie in the wire leaving each leg going out to the ground rods?
I've read that copper in contact with zinc (galvanized) is a no-no. I've
done as suggested by Polyphaser (although not always using their
products): I've used stainless steel strips (cannibalized from s/s hose
clamps) between the copper and the zinc. Using bronze clamps.
73
Alan NV8A