I see a cracked foundation in Figure 4 ... so where is the exploding
foundation?? My BS detector is turned on.
Subject: Re: [TowerTalk] exploding foundations
> What exploding concrete?? Back up your claim with real life validated
> proof. My experience has been the opposite.
>
> Doug
Want evidence? See Figure 4 (and the text below it) in the link below:
http://www.mikeholt.com/newsletters.php?action=display&letterID=407
According to NFPA 780, Ufer grounding is generally satisfactory provided
that it is not the only earth grounding mechanism and that the ground is
brought out beyond the concrete encasement to make the earth connection.
Exactly what I do.