Dana:

     For a small hole like that you probably can get away with poking at the 
concrete with a 2x4 piece of wood as it's being poured.  The goal is to 
ensure there are no voids or air pockets in the concrete after it sets up, 
thereby reducing the ultimate strength of the pour.

     My tower's foundation is made of 10.5 cuyds of concrete so I rented an 
electric vibrator for the project.  The 2x4 idea would not have been as 
effective for my project because of the volume of concrete, plus the 
foundation was undercut around the bottom edges and I wanted to make sure 
that that space was filled with mud.

73 de
Gene Smar  AD3F


----- Original Message ----- 
From: "Dana Roode" <dana.roode@gmail.com>
To: <towertalk@contesting.com>
Sent: Thursday, August 16, 2007 11:34 AM
Subject: [TowerTalk] Vibrator for 2x2x4 hole?


> Folks - for a 2x2x4' Rohn 25 base concrete foundation, do I need to
> use a concrete vibrator during the concrete pour?
>
>  dana
> _______________________________________________
>
>
>
> _______________________________________________
> TowerTalk mailing list
> TowerTalk@contesting.com
> http://lists.contesting.com/mailman/listinfo/towertalk 

_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk

<Prev in Thread] Current Thread [Next in Thread>